SP-5A 玻璃徐冷點及應變點試驗

SP-5A

玻璃徐冷點及應變點試驗

Annealing & Strain Point, (ASTM C-598 - Beam)

廠牌:ORTON/U.S.A.
供應商:建成科學儀器股份有限公司
聯絡電話:02-29103818
定價:與我們聯絡

快速詢價

5181

行動條碼QR Code
玻璃徐冷點及應變點試驗-行動條碼QR Code

 


 

The Orton Model SP-5A-DAS system is well suited for glasses that for one reason or another are not adaptable for flame working, or for applications where thermal expansion or effective length corrections (common to the fiber elongation method) are eliminated. The Orton Model SP-5A-DAS has been designed to automatically monitor the deformation of a 3-point loaded glass beam according to the ASTM C-598 method. Changes in the annealing and strain point temperatures can be used as an indication of changes in batch chemistry from raw material changes or batching errors.

Automatic Annealing and Strain Point Determination
  It takes 20 minutes to measure the Annealing and Strain Points of a glass rod or bar. It's simple. After the sample beam (rod or bar) is prepared, the operator simply places the beam into the furnace, enters the sample dimensions into the Orton on board computer, applies the weight, pushes the START button, and walks away. The system does the rest. The operator is free to perform other tasks. Twenty minutes later, the operator returns and reads the annealing point temperature on the display panel. It's that easy. The SP-5A-DAS automatically calculates the rate of deformation and displays the annealing point temperature which eliminates operator differences, judgements, and errors. If an independent computer system is connected to the SP-5A-DAS, both the annealing and strain point temperatures are calculated and displyed on the computer's monitor. The system automatically measures and records the rate of deformation and applies non-arbitrary mathematical algorithms to extrapolate the strain point temperature so operator differences, interpretations, judgments, and errors are eliminated. The Model SP-5A-DAS is a FAST, EASY, ACCURATE, RELIABLE, and REPRODUCIBLE method for QC checks on batch chemistry changes.

This system is comprised of the ASTM specified furnace to heat the sample beam, the Orton PID controller to operate the furnace according to the ASTM C598 thermal cycle, 2-point sample support system with midpoint sample load rod and weight, an LVDT system to continuously monitor the beam deformation, the Orton on board computer with internal logic to determine the annealing point, digital display panel for displaying the annealing point temperature, and software for an independent computer (provided by the purchaser).

Operation
The system is initially heated to an equilibrium soak temperature 25°C below the expected annealing point, and waits for the next test. The operator enters the beam dimensions into the on board computer, positions the beam on the sample support, applies the midpoint load rod, and adds the weight. As soon as the START button is pushed, the Orton controller heats the furnace at 5ºC per minute, and the on board computer captures the temperature and LVDT signals of the deforming beam and calculates the beam's deformation rate. Once the deformation rate exceeds a deformation rate corresponding to a viscosity of Log 12 P (a constant that is automatically calculated by the on board computer using the operator inputted beam dimensions and pre-programmed ASTM C598 equations), the Orton controller cools the furnace at 4°C per minute. While the furnace is cooling, the temperature and LVDT signals are captured by the controller's on board computer for storage. The test is automatically concluded when the temperature falls 10°C below the annealing point. The annealing point is the temperature at which an ASTM C598 specific deformation rate occurs. This rate is calculated by the on board computer using the operator inputted beam dimensions and pre-programmed ASTM C598 equations, and is displayed on the console display until the system is reset. The furnace automatically cools to the soak temperature in about 15 minutes, and is ready for the next test. The on board computer can store data for up to 10 tests.

If desired, a separate, independent computer system (not included) can be connected to the Orton controller console via a RS232 port for real time monitoring and analysis. During the test the beam deformation rate, time, and temperature are displayed on the monitor and stored on the hard drive in a text file. At the conclusion of the test, the software automatically and immediately calculates the annealing point temperature at which the ASTM C598 specific deformation rate occurs. This rate is calculated using the operator inputted beam dimensions and pre-programmed ASTM C598 equations. The software also automatically and immediately calculates the extrapolated strain point temperature, which is the temperature where the deformation rate is 0.0316 times the annealing deformation rate, according to the ASTM C598 algorithms.

Or, if preferred, a separate, independent computer system (not included) can be connected to the Orton controller console via a RS232 port after the test is concluded. The data stored by the Orton on board computer is transferred to the independent computer's hard drive in text file format for later independent review, analysis, or permanent storage.

Model SP-5A-DAS Specifications
Sample Length 50 mm (other lengths avail.)
Sample Cross Section 2.5 - 5 mm
Sample Support Fused Quartz
Sample Load Device Fused Quartz
Maximum Temperature 1,000°C
Heating Element Kanthal A-1
Temperature Control System PID - Automatic
Elongation Tracking System LVDT
Data Acquisition & Display Automatic
Power Requirements 120 VAC, 10 amp, 50/60 Hz (240 VAC available)
Measuring Unit Dimensions 12” W x 14” D x 33” T (305 x 355 x 840 mm)
Controller Dimensions 13” W x 12” D x 7” T (330 x 305 x 180 mm)

*Descriptions & specifications are subject to change without notice

  下載本目錄文件請使用 PDF 檔案程式
The Model SP-5A-DAS Brochure  is available for immediate downloading in a PDF format (642 KB).

您也可能對以下商品有興趣...

產品關鍵字:

大台北尖端儀器有限公司

最新廠商動態!

OMEGA ENGINEERING ;OMEGA代理;熱電偶接頭;熱電偶線;感溫線;偉吉達;
WHATMAN代理空氣採樣濾紙;玻璃纖維濾紙;G/A GF/B GF/C暨相關過濾素材; 2020 Cytiva代理Whatman濾膜及耗材;
不銹鋼三層推車;不銹鋼二層推車;實驗室推車;歡迎同業洽詢;
BROOKS質量流量控制器;PC540;BROOKS代理;質量流量控制器;BROOKS 5850E;
OMEGA ENGINEERING ;OMEGA 代理商;熱電偶接頭;熱電偶導線;熱電偶公母接頭;熱電偶感溫線;

更多

最新儀器!

力明儀器有限公司

Copyright © 2006-2017 tw17 All rights reserved.
Design: 台灣儀器網

台灣儀器網Tw17 行動條碼QR Code