The Model T101 H2S analyzer uses the proven UV fluorescence principle to measure hydrogen sulfide at levels commonly required for ambient air monitoring.
The Model T101 is equipped with an internally mounted catalytic converter set at 315°C to convert H2S to SO2. A switching mode alternately measures H2S and SO2 while showing both readings concurrently on the front display.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.
The Model T101 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
•Ranges: 0-50 ppb to 0-10 ppm H2S and up to 20 ppm SO2, user selectable
•Independent ranges and auto ranging
•Large, vivid, and durable color graphics display with touch screen interface
•Ethernet, RS-232, and (optional) USB com ports
•Front panel USB connections for peripheral devices and firmware upgrades
•8 analog inputs (optional)
•Adaptive signal filtering optimizes response time
•Temperature & pressure compensation
•Auto zero system
•Comprehensive internal data logging with programmable averaging periods
•Ability to log virtually any operating parameter
•Two-year warranty
•Ranges: H2S Min: 0 - 50 ppb full scale, Max: 0-10 ppm full scale. SO2 Up to 0-20 ppm full scale (selectable, dual range supported)
•Measurement Units: ppb, ppm, μg/m3, mg/m3 (selectable)
•Zero Noise: < 0.2 ppb (RMS)
•Span Noise: < 0.5% of reading (RMS) above 50 ppb
•Lower Detectable Limit: 0.4 ppb
•Zero Drift: < 0.5 ppb/24 hours
•Span Drift: < 0.5% of full scale/24 hours
•Lag Time: 20 seconds
•Rise/Fall Time: < 120 seconds to 95%
•Linearity: 1% of full scale
•Precision: 0.5% of reading above 50 ppb
•Sample Flow Rate: 650 cc/min ±10%
•Power Requirements: 100V-120V, 220V-240V, 50/60 Hz
•Analog Output Ranges: 10V, 5V, 1V, 0.1V (selectable)
•Recorder Offset: ±10%
•Included I/O: 1 x Ethernet: 10/100Base-T, 2 x RS232 (300-115,200 baud), 2 x USB device ports, 8 x opto-isolated digital outputs, 6 x opto-isolated digital inputs, 4 x analog outputs
•Optional I/O: 1 x USB com port, 1 x RS485, 8 x analog inputs (0-10V, 12-bit), 4 x digital alarm outputs, Multidrop RS232, 3 x 4 - 20mA current outputs
•Operating Temperature Range: 5 - 40ºC
•Dimensions (HxWxD): 7" x 17" x 23.5" (178 x 432 x 597 mm)
•Weight: Analyzer 41 lbs (18.3 kg)