廠牌:Beckman
供應商:台大科學儀器有限公司
聯絡電話:02-2325-5679 02-2533-6586
快速詢價 |
For general purpose pH measurements. Features 1 m long integrated cable with BNC connector. Electrodes with epoxy body have a protective design in which body extends over glass bulb measuring surface. Uses storage and filling solution A60217. |
Part No. | Description | pH Range | Temp. Range | Body Material | Diameter | Length |
---|---|---|---|---|---|---|
A57177 | Gel-Filled | 0 to 14 | 0 to 80°C | Epoxy | 12 (mm) | 150 (mm) |
A57186 | Refillable | 0 to 14 | 0 to 100°C | Epoxy | 12 (mm) | 150 (mm) |
A57181 | Refillable | 0 to 14 | 0 to 100°C | Glass | 12 (mm) | 150 (mm) |
A57180 | Semi-Micro, Gel-Filled | 0 to 14 | 0 to 80°C | Epoxy | 6 (mm) | 150 (mm) |
A57187 | Semi-Micro, Refillable | 0 to 14 | 0 to 100°C | Epoxy | 6 (mm) | 150 (mm) |
A57183 | Semi-Micro, Refillable | 0 to 14 | 0 to 100°C | Glass | 6 (mm) | 150 (mm) |
A57179 | Flask, Gel-Filled | 0 to 14 | 0 to 80°C | Epoxy | 9.5 (mm) | 300 (mm) |
A57182 | Flask, Refillable | 0 to 14 | 0 to 100°C | Glass | 9.5 (mm) | 300 (mm) |
Calomel pHree electrodes for biological applications are a mercury-free alternative to traditional calomel electrodes. Electrodes have a silver-ion trap that effectively acts as a third junction to prevent contamination of sample and junction area of electrodes. Unique chemistry allows electrode to deliver comparable performance to calomel electrode, while creating fewer precautions for handling and disposal. Electrodes feature 1m long integrated cable with BNC connector. Electrodes with epoxy body have a protective design in which body extends over glass bulb measuring surface. Uses storage and filling solution A51713. |
Part No. | Description | pH Range | Temp. Range | Body Material | Diameter | Length |
---|---|---|---|---|---|---|
A51705 | Gel-Filled | 0 to 14 | 0 to 60°C | Epoxy | 12 (mm) | 150 (mm) |
A51706 | Gel-Filled | 0 to 14 | 0 to 60°C | Glass | 12 (mm) | 150 (mm) |
A51707 | Refillable | 0 to 14 | 0 to 60°C | Epoxy | 12 (mm) | 150 (mm) |
A51708 | Refillable | 0 to 14 | 0 to 60°C | Glass | 12 (mm) | 150 (mm) |
A51711 | Semi-Micro, Gel-Filled | 0 to 14 | 0 to 60°C | Epoxy | 6 (mm) | 150 (mm) |
A51712 | Semi-Micro, Gel-Filled | 0 to 14 | 0 to 60°C | Glass | 6 (mm) | 150 (mm) |
A51709 | Flask, Gel-Filled | 0 to 14 | 0 to 60°C | Epoxy | 9.5 (mm) | 300 (mm) |
A51710 | Flask, Gel-Filled | 0 to 14 | 0 to 60°C | Glass | 9.5 (mm) | 300 (mm) |
3-in-1 Probe
Combination gel-filled pH electrode with built-in automatic temperature compensation. Features 1m long integrated cable with BNC connector. Rugged epoxy body extends over glass bulb measuring surface for protection. Uses storage solution A60217. |
Part No. | Description | pH Range | Temp. Range | Body Material | Diameter | Length |
---|---|---|---|---|---|---|
A57198 | 3-in-1, Gel-Filled | 0 to 14 | 0 to 80°C | Epoxy | 12 (mm) | 150 (mm) |
Temperature Probe for Φ Series Meters
Temperature Probe designed for use with Beckman Coulter Φ Series meters. Features 1m long integrated cable. |
Part No. | Description | Diameter | Temp. Range | Body Material | Length |
---|---|---|---|---|---|
A58722 | Temperature Probe | 6 (mm) | 0 to 100°C | Epoxy | 150 (mm) |
Combination Double Junction Spear-Tipped pH electrode
For pH measurement in food and other samples, spear-tipped design with rugged epoxy body features 1 m long integrated cable with BNC connector. Uses storage and filling solution A60217. |
Part No. | Description | pH Range | Temp. Range | Body Material | Diameter | Length |
---|---|---|---|---|---|---|
A57185 | Double Junction, Gel-Filled, Spear-tipped | 0 to 14 | 0 to 80°C | Epoxy | 9.5 (mm) | 150 (mm) |
Combination Double Junction Flat-Bulb pH Electrode
For pH measurement in thick or oily samples, or surface measurement of gels. Features 1 m long integrated cable with BNC connector. Uses storage solution A60217. |
Part No. | Description | pH Range | Temp. Range | Body Material | Diameter | Length |
---|---|---|---|---|---|---|
A57184 | Double Junction, Gel-Filled, Flat-Bulb | 0 to 14 | 0 to 80°C | Epoxy | 12 (mm) | 150 (mm) |
Combination Double Junction pH Electrode
For pH measurement of sulfides, heavy metals, or other materials that interact with silver. Features 1 m long cable with BNC connector. Uses storage solution A60217. |
Part No. | Description | pH Range | Temp. Range | Body Material | Diameter | Length |
---|---|---|---|---|---|---|
A57178 | Double Junction, Gel-Filled | 0 to 14 | 0 to 80°C | Epoxy | 12 (mm) | 150 (mm) |
For low ionic solutions with conductivity below 100 microsiemens, such as DI water. Features 1 m long integrated cable with BNC connector. Uses storage and filling solution A58729. |
Part No. | Description | pH Range | Temp. Range | Body Material | Diameter | Length |
---|---|---|---|---|---|---|
A57195 | Low Ionic Strength, Refillable | 0 to 14 | 0 to 100°C | Epoxy | 12 (mm) | 150 (mm) |
A57196 | Low Ionic Strength, Refillable | 0 to 14 | 0 to 100°C | Glass | 12 (mm) | 150 (mm) |
For pH measurement in highly viscous or “dirty” samples such as soil, sludges, or slurries. To prevent clogging, junction can be renewed after each use by simply pressing electrode cap to flush junction with filling solution. Ideal for use with TRIS buffers. Electrode with epoxy body has protective design where epoxy body extends over glass measurement bulb. Features 1 m long integrated cable with BNC connector. Uses storage and filling solution 511469. |
Part No. | Description | pH Range | Temp. Range | Body Material | Junction | Diameter | Length |
---|---|---|---|---|---|---|---|
511110 | Refillable | 0 to 14 | 0 to 100°C | Epoxy | Ground Sleeve | 12 (mm) | 130 (mm) |
511111 | Refillable | 0 to 14 | 0 to 100°C | Glass | Ground Sleeve | 12 (mm) | 125 (mm) |
For use when indicating element must physically be separated from reference element to reduce noise, or when a different reference element is needed to precisely match the sample being measured. All electrodes feature a 1 meter long integrated cable; indicating electrodes have BNC connector, reference electrodes have pin connector. Calomel pHree Reference Electrodes use storage and filling solution A51713. Ag/AgCl Reference Electrodes use storage and filling solution A60217. |
Part No. | Description | pH Range |
Temp Range |
Body Material |
Diameter | Length |
---|---|---|---|---|---|---|
A57188 | Indicating Electrode (Measurement Half Cell) | 0 to 14 | 0 to 100°C | Epoxy | 12 (mm) | 150 (mm) |
A57189 | Indicating Electrode (Measurement Half Cell) | 0 to 14 | 0 to 100°C | Glass | 12 (mm) | 150 (mm) |
A57190 | Reference, Gel-filled, Calomel pHree |
- |
0 to 60°C | Epoxy | 12 (mm) | 150 (mm) |
A57192 | Reference, Refillable, Calomel pHree |
- |
0 to 60°C | Glass | 12 (mm) | 150 (mm) |
A57193 | Reference, Gel-Filled, Ag/AgCl |
- |
0 to 80°C | Epoxy | 12 (mm) | 150 (mm) |
A57194 | Reference, Refillable, Ag/AgCl |
- |
0 to 100°C | Glass | 12 (mm) | 150 (mm) |